2014年1月9日星期四

Huawei Switch: Two Connected Optical Ports Cannot Turn Up

What Can I Do If Two Connected Optical Ports Cannot Turn Up of Huawei switch? Such as S2700-26TP-EI-AC, S3700-28TP-SI-AC

Do the following if two connected optical ports cannot be up:
1. Check the port configurations. Ensure that the two ports are not shut down and have the
same duplex mode, rate, and negotiation mode.
2. Check the optical modules and fibers. Ensure that the two ports use the same type of optical
modules, and the port rate is the same as the rate of optical modules. The optical modules
must match the fibers. Single-mode fibers are inserted into single-mode optical modules
and the multi-mode fibers are inserted into multi-mode optical modules.
3. Check whether the receive or transit power of the optical ports is within the allowed range.
If the receive or transmit power is excessively high or low, ports cannot turn Up. The
excessively long transmission distance or low optical fiber quality may also be the reason
why ports cannot turn Up.

4. If the preceding items are all normal, perform internal loopback test on the ports. Connect
the head and tail of a fiber to an optical module to check whether the port can go Up.
You can also run the loopback internal command in the interface view to configure the
loopback function on Ethernet ports. This function can test port hardware performance
without connecting optical fibers to the port. If the port is Up, the port hardware is in good
condition.
5. If the fault cannot be located after the preceding operations are performed, replace the
optical modules or fibers.
Reference commands: